Maternal cardiovascular hemodynamics in normotensive versus preeclamptic pregnancies: a prospective longitudinal study using a noninvasive cardiac system (NICaS™)

正常血压妊娠与先兆子痫妊娠中母体心血管血流动力学的比较:一项使用无创心脏系统(NICaS™)的前瞻性纵向研究

阅读:1

Abstract

BACKGROUND: Preeclampsia is among the most common medical complications of pregnancy. The clinical utility of invasive hemodynamic monitoring in preeclampsia (e.g., Swan-Ganz catheter) is controversial. Thoracic impedance cardiography (TIC) and Doppler echocardiography are noninvasive techniques but they both have important limitations. NICaS™ (NI Medical, PetachTikva, Israel) is a noninvasive cardiac system for determining cardiac output (CO) that utilizes regional impedance cardiography (RIC) by noninvasively measuring the impedance signal in the periphery. It outperformed any other impedance cardiographic technology and was twice as accurate as TIC. METHODS: We used the NICaS™ system to compare the hemodynamic parameters of women with severe preeclampsia (PET group, n = 17) to a cohort of healthy normotensive pregnant women with a singleton pregnancy at term (control group, n = 62) (1/2015-6/2015). Heart rate (HR), stroke volume (SV), CO, total peripheral resistance (TPR) and mean arterial pressure (MAP) were measured 15-30 min before CS initiation, immediately after administering spinal anesthesia, immediately after delivery of the fetus and placenta, at the abdominal fascia closure and within 24-36 and 48-72 h postpartum. RESULTS: The COs before and during the CS were significantly higher in the control group compared to the PET group (P < .05), but reached equivalent values within 24-36 h postpartum. CO peaked at delivery of the newborn and the placenta and started to decline afterwards in both groups. The MAP and TPR values were significantly higher in the PET group at all points of assessment except at 48-72 h postpartum when it was still significantly higher for MAP while the TPR only exhibited a higher trend but not statistically significant. The NICaS™ device noninvasively demonstrated low CO and high TPR profiles in the PET group compared to controls. CONCLUSIONS: The immediate postpartum period is accompanied by the most dramatic hemodynamic changes and fluid shifts, during which the parturient should be closely monitored. The NICaS™ device may help the clinician to customize the most optimal management for individual parturients. Our findings require validation by further studies on larger samples.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。