Endovascular Treatment of Posterior Circulation Saccular Aneurysms With the p64 Flow Modulation Device: Mid-and Long-Term Results in 54 Aneurysms From a Single Center

采用p64血流调节装置进行后循环囊状动脉瘤的血管内治疗:单中心54例动脉瘤的中长期疗效

阅读:1

Abstract

Objective: Flow diverter (FD) stents have become one of the most common tools for treating intracranial aneurysms; however, their role in treating posterior circulation aneurysms is still discussed with controversy. In this study, we evaluated the safety and effectiveness of p64 FD for the treatment of saccular, unruptured aneurysms in the posterior circulation over a long-term follow-up period in a single center. Methods: From our prospectively maintained database, we retrospectively identified patients who underwent treatment of an intracranial saccular aneurysm arising from the posterior circulation with ≥1 p64 FD implanted or attempted between October 2012 and December 2019. Aneurysms could have been treated with prior or concomitant saccular treatment (e.g., coiling, intra-aneurysmal flow diversion). Aneurysms with parent vessel implants other than p64, fusiform aneurysms, and dissections were excluded. Peri- and postprocedural complications, clinical outcome, and clinical and angiographic follow-up results were evaluated. Results: In total, 54 patients (45 female, 9 male; mean age 55.1 years) with 54 intracranial aneurysms met the inclusion criteria. In 51 cases (94.4%), one p64 was implanted; in 2 cases (3.7 %), two p64s were implanted; in one case, deployment of the p64 was not feasible. Procedural complications occurred in 3.7% and postprocedural complications in 9.3 %, respectively. Hemorrhagic complications occurred in 2/54 patients (3.7%), thereof one fatal parenchymal hemorrhage. Ischemic complications were observed in 5/54 patients (9.3%). Early, mid-term, and long-term angiographic follow-up examinations showed complete or near-complete aneurysm occlusion, defined according to the O'Kelly -Marotta (OKM) scale as OKM C + D in 56, 75.6, and 82.9 %, respectively. Asymptomatic side vessel occlusions occurred in 3.8%, each during the first follow-up. Conclusions: The implantation of a p64 FD is a safe and effective device for endovascular treatment of posterior circulation saccular aneurysms with a high success rate and low morbi-mortality.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。