Influence factors on the critical micelle concentration determination using pyrene as a probe and a simple method of preparing samples

以芘为探针测定临界胶束浓度的影响因素及一种简便的样品制备方法

阅读:1

Abstract

The critical micelle concentration (CMC) is an important parameter of widely used surfactants and needs to be measured in the application and development of surfactants. Fluorometric method is a widely used method determining CMC values owing to the advantages of highly sensitivity, fast response and wide application range. There are two common methods (I and II) of preparing samples for CMC fluorometric determination. In the process of developing CMC probes with aggregation-induced emission (AIE) characteristics, we found that methods I and II were not suitable for CMC probes with AIE charateristics and developed a new sample preparation method (III), which is not only suitable for CMC probes with AIE characteristic but also decreases operation procedures and errors owing to omitting the addition of micro amount of dyes into each sample. To ascertain if method III is also suitable for other CMC probes without AIE characteristics, the CMC values of surfactants were determined by fluorometric method using widely used pyrene without AIE charateristic as probe and methods I-III to prepare samples. The obtained experimental results proved that method III not only was suitable for preparation of samples for CMC determination of surfactants using pyrene as probe but also led to the least average deviation (methods I-III led to ±0.13, ±0.34 and ±0.05 mM deviation for the CMC determination of sodium dodecyl sulfate (SDS), respectively). The CMC determination using pyrene as probe is based on its change in the ratio (I (FIII)/I (FI)) of its emission peaks I and III with surfactant concentration. Unexpectedly, it was found that the I (FIII)/I (FI) value of pyrene in surfactant solutions is sensitive to the measurement conditions changing exciting light energy, such as slit widths and sample-measured number. In addition, it was found that surfactant SDS or cetrimonium bromide from different suppliers not only has significantly different CMC values but also leads to very different I (FIII)/I (FI) values of pyrene in a certain concentration of surfactant, which can be used as a simple method to distinguish the same surfactant with different CMC values.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。