Computational Assessment of Magnetic Nanoparticle Targeting Efficiency in a Simplified Circle of Willis Arterial Model

在简化的Willis环动脉模型中对磁性纳米粒子靶向效率进行计算评估

阅读:1

Abstract

This paper presents the methodology and computational results of simulated medical drug targeting (MDT) via induced magnetism intended for administering intravenous patient-specific doses of therapeutic agents in a Circle of Willis (CoW) model. The multi-physics computational model used in this work is from our previous works. The computational model is used to analyze pulsatile blood flow, particle motion, and particle capture efficiency in a magnetized region using the magnetic properties of magnetite (Fe(3)O(4)) and equations describing the magnetic forces acting on particles produced by an external cylindrical electromagnetic coil. A Eulerian-Lagrangian technique is implemented to resolve the hemodynamic flow and the motion of particles under the influence of a range of magnetic field strengths (B(r) = 2T, 4T, 6T, and 8T). Particle diameter sizes of 10 nm to 4 µm in diameter were assessed. Two dimensionless numbers are also investigated a priori in this study to characterize relative effects of Brownian motion (BM), magnetic force-induced particle motion, and convective blood flow on particle motion. Similar to our previous works, the computational simulations demonstrate that the greatest particle capture efficiency results for particle diameters within the micron range, specifically in regions where flow separation and vortices are at a minimum. Additionally, it was observed that the capture efficiency of particles decreases substantially with smaller particle diameters, especially in the superparamagnetic regime. The highest capture efficiency observed for superparamagnetic particles was 99% with an 8T magnetic field strength and 95% with a 2T magnetic field strength when analyzing 100 nm particles. For 10 nm particles and an 8T magnetic field strength, the particle capture efficiency was 48%, and for a 2T magnetic field strength the particle capture efficiency was 33%. Furthermore, it was found that larger magnetic field strengths, large particle diameter sizes (1 µm and above), and slower blood flow velocity increase the particle capture efficiency. The key finding in this work is that favorable capture efficiencies for superparamagnetic particles were observed in the CoW model for weak fields (B(r) < 4T) which demonstrates MDT as a possible viable treatment candidate for cardiovascular disease.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。