A Conceptual Approach to Reduce the Product Gas Crossover in Alkaline Electrolyzers

减少碱性电解槽中产物气体交叉的概念方法

阅读:1

Abstract

The crossover of the product gases hydrogen and oxygen in alkaline electrolyzer operation is a critical factor, severely limiting the operational window in terms of current density and pressure. In prior experiments, it was found that a large degree of oversaturation of the reaction products in the liquid electrolyte phase leads to high amounts of crossover. We are proposing to reduce this amount of oversaturation by introducing micro-cracks in the Zirfon diaphragm. These cracks are meant to induce the formation of hydrogen and oxygen bubbles on the respective sides, and thereby reduce the oversaturation and amount of crossover. In theory, the size of the bubble corresponds to the size of the cracks, and from our computational fluid dynamics simulations, we conclude that the bubbles should be as large as possible to minimize the ohmic resistance in the electrolyte phase. The results suggest that an increase in bubble diameter from 50 microns to 150 microns results in a 10% higher current density at a cell voltage of 2.1 V.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。