Domestic mite antigens in floor and airborne dust at workplaces in comparison to living areas: a new immunoassay to assess personal airborne allergen exposure

工作场所地板和空气灰尘中的家居螨虫抗原与生活区域的比较:一种评估个人空气过敏原暴露的新型免疫测定法

阅读:5
作者:Ingrid Sander, Eva Zahradnik, Gerhard Kraus, Stefan Mayer, Heinz-Dieter Neumann, Christina Fleischer, Thomas Brüning, Monika Raulf-Heimsoth

Conclusions

A new sensitive EIA directed at DM antigens was developed. DM antigen quantities were well correlated to Der f 1 values and were measurable in the majority (87%) of airborne dust samples. Some workplaces had significantly higher DM antigen concentrations than living areas.

Methods

At workplaces and in living areas, 213 floor dust samples and 92 personal inhalable dust samples were collected. For sensitive quantification of DM antigens, a new enzyme immunoassay (EIA) based on polyclonal antibodies to Dermatophagoides farinae extract was developed. Reactivity of five house dust mite and four storage mite species was tested. All dust samples were tested with the new EIA and with the Der f 1 and Der p 1-EIAs (Indoor Biotechnologies, UK) which detect major allergens from D. farinae and D. pteronyssinus by monoclonal antibodies. Samples below the detection limit in the DM-EIA were retested in an assay variant with a fluorogenic substrate (DM-FEIA).

Results

The newly developed DM-EIA detects antigens from all nine tested domestic mite species. It has a lower detection limit of 200 pg/ml of D.farinae protein, compared to 50 pg/ml for the DM-FEIA. DM antigens were detected by DM-EIA/FEIA in all floor dust and 80 (87%) of airborne samples. Der f 1 was found in 133 (62%) floor dust and in only 6 airborne samples, Der p 1 was found in 70 (33%) of floor samples and in one airborne sample. Der f 1 and DM concentrations were highly correlated. DM-antigens were significantly higher in inhalable airborne samples from textile recycling, bed feather filling, feed production, grain storage and cattle stables in comparison to living areas. Conclusions: A new sensitive EIA directed at DM antigens was developed. DM antigen quantities were well correlated to Der f 1 values and were measurable in the majority (87%) of airborne dust samples. Some workplaces had significantly higher DM antigen concentrations than living areas.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。