Energy, exergy, and environmental assessment of a small-scale solar organic Rankine cycle using different organic fluids

利用不同有机流体对小型太阳能有机朗肯循环进行能量、㶲和环境评估

阅读:1

Abstract

This article presents an energetic, exergetic, and environmental (3E) analysis of a solar powered simple Rankine Organic Cycle (ORC). The ORC is simulated using three organic working fluids, such as Toluene, Cyclohexane, and Acetone, meanwhile the solar system uses thermal oil Therminol 75. The present study shows the performance of this coupled system using historical solar annual radiation data from four of the highest solar potential locations in Colombia. Data used correspond to data for the cities Rancho Grande, Puerto Bolivar, Manaure, and Nazareth. Simulations were performed using commercial programs as MATLAB® and REFPROP 9.0. Energy production, the energy and exergetic efficiencies of the system, the exergy destruction was calculated based on the input of the global solar radiation. Effects generated by each working fluid in the solar powered ORC system was determined. It was stablished that the heat obtained in the solar collector in combination with a storage tank is incorporated during non-radiation hours guarantees the thermal stability of the working fluid in the ORC. The best performance corresponds to the Rancho Grande city, being the Toluene the corresponding working fluid with the highest energy (14.6%) and exergetic (7.37%) efficiencies, as well as the maximum power generation (5.50 kW) for October month, meanwhile, the highest exergy destruction values correspond in April. A sensitivity analysis of the individual elements of the system was performed. This study revealed the preference of a lower evaporator pinch point temperature, higher turbine thermal efficiency, pump thermal efficiency, and pressure ratio to obtain better energy and exergy efficiency of the solar powered ORC system. Additionally, the potential environmental impact of the system was evaluated through a Life Cycle Analysis, obtaining for the solar system solar collector has the highest environmental impact with 78557850 mPts. Meanwhile for the ORC, the turbine registers the most significant environmental impact with 295516 mPts (7.34%), when Toluene is used as a working fluid and copper as a construction material in the location of Rancho Grande. In conclusion, the potentiality of planning the operation of solar powered ORC was successfully evaluated for four specific locations in Colombia.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。