A comparative study of dentinal tubule penetration and the retreatability of EndoSequence BC Sealer HiFlow, iRoot SP, and AH Plus with different obturation techniques

EndoSequence BC Sealer HiFlow、iRoot SP 和 AH Plus 与不同充填技术的牙本质小管渗透性和可重复性的比较研究

阅读:5
作者:Ruiqi Yang, Jun Tian, Xiangya Huang, Shuxiang Lei, Yanling Cai, Zhezhen Xu, Xi Wei

Conclusions

HiFlow/CWC technique showed better performance in dentinal tubule penetration than that of iRoot SP/SC. Both HiFlow and iRoot SP combined with CWC technique groups required more retreatment time than the other groups. Furthermore, using HiFlow with either the CWC or SC technique left less remaining sealer at 4-mm level than using AH Plus with the CWC technique during retreatment. Clinical relevance: With favorable performance in dentinal tubule penetration and retreatability in endodontic retreatment, the combined use of EndoSequence BC Sealer HiFlow with the recommended continuous wave condensation technique may be a worthwhile choice in root canal treatment.

Methods

Sixty-five single-rooted teeth were instrumented and randomly divided into 5 groups: group 1, AH Plus/CWC; group 2, iRoot SP/CWC; group 3, iRoot SP/SC; group 4, HiFlow/CWC; and group 5, HiFlow/SC. The ability to re-establish patency during endodontic retreatment was recorded, as was the time taken to reach the working length. Dentinal tubule penetration and remaining debris after retreatment were evaluated by confocal microscopy and scanning electron microscopy. Data were analyzed by Kruskal-Wallis test and Dunn's multiple comparisons test (α = 0.05).

Results

The HiFlow/CWC and iRoot SP/CWC groups required more time to reach the working length than groups that underwent the SC technique regardless of the sealer used (P < .05). The HiFlow/CWC group showed a significantly higher percentage of sealer penetration area than that of the iRoot SP/SC at 4 mm from the apex (P < .05) and penetrated deeper into dentinal tubules than iRoot SP/SC at both 8-mm and 12-mm levels (P < .05). Moreover, the HiFlow/CWC and HiFlow/SC groups demonstrated less remaining sealer along the canal wall than AH Plus/CWC group at 4-mm level (P < .05). Conclusions: HiFlow/CWC technique showed better performance in dentinal tubule penetration than that of iRoot SP/SC. Both HiFlow and iRoot SP combined with CWC technique groups required more retreatment time than the other groups. Furthermore, using HiFlow with either the CWC or SC technique left less remaining sealer at 4-mm level than using AH Plus with the CWC technique during retreatment. Clinical relevance: With favorable performance in dentinal tubule penetration and retreatability in endodontic retreatment, the combined use of EndoSequence BC Sealer HiFlow with the recommended continuous wave condensation technique may be a worthwhile choice in root canal treatment.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。