Prolonged circulatory support with an Impella assist device in the management of cardiogenic shock associated with takotsubo syndrome, severe sepsis and acute respiratory distress syndrome

使用 Impella 辅助装置进行长时间循环支持,用于治疗与 Takotsubo 综合征、严重脓毒症和急性呼吸窘迫综合征相关的心源性休克。

阅读:1

Abstract

Severe sepsis has been known to trigger for takotsubo syndrome which is associated with profound physical or emotional stress. Severe sepsis is also associated with sepsis-induced cardiomyopathy, a reversible myocardial depression. We report a case in which a patient with takotsubo syndrome, cardiogenic shock, severe sepsis, and adult respiratory distress syndrome was managed with an Impella Cardiac Power circulatory support device for 108 h (4.5 days) because of sustained hemodynamic compromise. To the best of our knowledge, this represents the longest reported use of the Impella Cardiac Power device for the management of cardiogenic shock in a patient with takotsubo syndrome and severe sepsis. This report also highlights the importance of considering a ventricular assist device in the management of takotsubo syndrome cardiogenic shock with severe sepsis which is unresponsive to maximal medical therapy.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。