Addition of Exogenous γ-Glutamyl Hydrolase Eliminates the Need for Lengthy Incubation of Whole-Blood Lysate for Quantitation of Folate Vitamers by High-Performance Liquid Chromatography-Tandem Mass Spectrometry

添加外源性γ-谷氨酰水解酶可消除高效液相色谱-串联质谱法定量叶酸维生素时对全血裂解液进行长时间孵育的需要。

阅读:1

Abstract

BACKGROUND: Measurement of folate monoglutamates by HPLC-tandem mass spectrometry (HPLC-MS/MS) in whole-blood lysate (WBL) requires lengthy incubation before analysis, risking degradation of labile folate vitamers. OBJECTIVE: We explored whether the addition of a commercially available recombinant exogenous γ-glutamyl hydrolase (exoGGH) enzyme reduced the required incubation time of WBL for measurement of folate as monoglutamates. METHODS: For conventional deglutamylation of polyglutamates, WBL was incubated for 4 h at 37°C. Alternatively, we added exoGGH to WBL at varying concentrations (1-10 µg/mL) and incubation times (0-90 min). We also investigated modifications to the sample diluent (pH, ascorbic acid compared with sodium ascorbate, and ascorbate concentration). Finally, we tested the effect of the enzyme in different sample types: WBL from frozen whole blood compared with frozen WBL or with frozen washed RBCs. Samples (n ≤ 15/experiment) were analyzed by HPLC-MS/MS for 6 folate monoglutamates and 5-methyltetrahydrofolate diglutamate. RESULTS: Optimal deconjugation of folate polyglutamates was achieved by using 1% ascorbic acid and 5 µg enzyme/mL WBL, requiring ≤30 min incubation time to achieve complete folate recovery as monoglutamates. This treatment resulted in similar folate concentrations as conventional deglutamylation (4 h at 37°C). The exoGGH enzyme was effective in samples stored frozen as whole blood and as WBL. However, the extended thaw time of whole blood resulted in 5-methyltetrahydrofolate loss and unacceptable changes to the non-methyl folate concentration. Total folate (with exoGGH) measured in washed RBCs was ∼15% lower than RBC folate calculated from WBL concentrations (conventional deglutamylation). CONCLUSIONS: The use of exoGGH minimized incubation time and thus may avoid degradative losses of labile folate forms during sample preparation. The lower folate results in washed RBCs may be due to inadequate packing of RBCs, among other unidentified factors. A larger study is required to confirm the lack of differences in folate concentrations determined with and without the use of exoGGH.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。