Preliminary analysis of stimulation parameters for sacral neuromodulation in different indications: a multicenter retrospective cohort study from China

骶神经调控不同适应症刺激参数的初步分析:一项来自中国的多中心回顾性队列研究

阅读:3

Abstract

BACKGROUND: Sacral neuromodulation (SNM) is an effective approach for treating lower urinary tract dysfunction (LUTD), and stimulation programming is essential for successful treatment. However, research on SNM programming for various indications is limited. Thus, the authors aimed to determine whether there were differences in the stimulation parameters for different SNM indications and the appropriate programming recommendations. MATERIALS AND METHODS: Clinical data were retrospectively collected from patients with LUTD who underwent SNM and completed internal pulse generator implantation. The parameters with the highest patient satisfaction or the most symptom improvement during the test period were considered optimal and used to set the programming after internal pulse generator implantation. RESULTS: After screening, 282 patients were enrolled and categorized into four groups based on the following indications: refractory overactive bladder (OAB) ( n =61), neurogenic lower urinary tract dysfunction (nLUTD) ( n =162), interstitial cystitis/painful bladder syndrome (IC/BPS) ( n =24), and idiopathic nonobstructive urinary retention (NOUR) ( n =35). When analyzing the optimal stimulus parameters, disparities in the stimulation amplitude and pulse frequency were noted among the four groups. The stimulation amplitude in the nLUTD group was higher than that in the idiopathic NOUR group ( P =0.013). Differences in pulse frequency were observed between the refractory OAB and nLUTD groups ( P <0.001) and between the refractory OAB and idiopathic NOUR groups ( P =0.001). No differences in the electrode configuration or pulse width settings existed among the four groups. CONCLUSIONS: The stimulation parameters for SNM varied among the different indications. For the initial programming of stage I, most patients are recommended to start with stimulation amplitudes below 2 V, although patients with nLUTD may benefit from higher amplitudes. A standard pulse width of 210 μs is recommended for all patients. However, for individuals experiencing nLUTD or idiopathic NOUR, the pulse frequency can begin above the standard 14 Hz but not exceed 50 Hz.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。