Outcome of a second two-stage reimplantation for periprosthetic knee infection

第二次两阶段翻修术治疗假体周围膝关节感染的结果

阅读:1

Abstract

Recurrent or persistent infection after two-stage exchange arthroplasty for previously infected total knee replacement is a challenging clinical situation. We asked whether a second two-stage procedure could eradicate the infection and preserve knee function. We evaluated 18 selected patients with failed two-stage total knee arthroplasty implantation treated with a second two-stage reimplantation between 1999 and 2005. Failure of treatment was defined as recurrence or persistence of infection. The minimum followup was 24 months (mean, 40 months; range, 24-83 months). Recurrent or persistent infection was diagnosed in four of 18 patients, two of whom were successfully treated with a third two-stage exchange arthroplasty. Knee Society score questionnaires administered at the last followup showed an average Knee Society knee score of 73 points (range, 24-100 points) and an average functional score of 49 points (range, 20-90 points). The data suggest repeat two-stage exchange arthroplasty is a reasonable option for eradicating periprosthetic infection, relieving pain, and achieving a satisfactory level of function for some patients. LEVEL OF EVIDENCE: Level IV, therapeutic study.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。