Bone Coverage around Hydroxyapatite/Poly((L)-Lactide) Composite Is Determined According to Depth from Cortical Bone Surface in Rabbits

兔体内羟基磷灰石/聚乳酸复合材料周围的骨覆盖率是根据距皮质骨表面的深度来确定的

阅读:1

Abstract

Composites of unsintered hydroxyapatite (HA) and poly((L)-lactide) (PLLA) reinforced by compression forging are biodegradable, bioactive, and have ultrahigh strength. However, foreign body reactions to PLLA and physical irritation can occur when not covered by bone. We aimed to confirm the relationships between the depth of the implanted HA-PLLA threaded pins and the new bone formation. We inserted HA-PLLA composite threaded pins (diameter: 2.0 or 4.5 mm) into the femoral and tibial bones of 32 mature male Japanese white rabbits (weight 3.0-3.5 kg) with the pin head 1 or 0 mm below or protruding 1 or 2 mm above surrounding cortical bone. Eight euthanized rabbits were radiologically and histologically assessed at various intervals after implantation. Bone bridging was complete over pins of both diameters at ~12 weeks, when inserted 1 mm below the surface, but the coverage of the pins inserted at 0 mm varied. Bone was not formed when the pins protruded >1 mm from the bone surface. No inflammation developed around the pins by 25 weeks. However, foreign body reactions might develop if composites are fixed above the bone surface, and intraosseous fixation would be desirable using double-threaded screws or a countersink to avoid screw head protrusion.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。