Deep inspiration breath-hold for left-sided breast irradiation: Analysis of dose-mass histograms and the impact of lung expansion

左侧乳腺放射治疗中深吸气屏气:剂量质量直方图分析及肺扩张的影响

阅读:1

Abstract

BACKGROUND: The aim of this study was to compare dose-volume histogram (DVH) with dose-mass histogram (DMH) parameters for treatment of left-sided breast cancer in deep inspiration breath-hold (DIBH) and free breathing (FB). Additionally, lung expansion and anatomical factors were analyzed and correlated to dose differences. METHODS: For 31 patients 3D conformal radiation therapy plans were retrospectively calculated on FB and DIBH CTs in the treatment planning system. The calculated doses, structures and CT data were transferred into MATLAB and DVHs and DMHs were calculated. Mean doses (Dmean), volumes and masses receiving certain doses (Vx, Mx) were determined for the left lung and the heart. Additionally, expansion of the left lung was evaluated using deformable image registration. Differences in DVH and DMH dose parameters between FB and DIBH were statistically analyzed and correlated to lung expansion and anatomical factors. RESULTS: DIBH reduced Dmean (DVH) and relative V20 (V20 [%]) of the left lung in all patients, on average by - 19 ± 9% (mean ± standard deviation) and - 24 ± 10%. Dmean (DMH) and M20 [%] were also significantly reduced (- 12 ± 11%, - 16 ± 13%), however 4 patients had higher DMH values in DIBH than in FB. Linear regression showed good correlations between DVH and DMH parameters, e.g. a dosimetric benefit smaller than 8.4% for Dmean (DVH) in DIBH indicated more irradiated lung mass in DIBH than in FB. The mean expansion of the left lung between FB and DIBH was 1.5 ± 2.4 mm (left), 16.0 ± 4.0 mm (anterior) and 12.2 ± 4.6 mm (caudal). No significant correlations were found between expansions and differences in Dmean for the left lung. The heart dose in DIBH was reduced in all patients by 53% (Dmean) and this dosimetric benefit correlated to lung expansion in anterior. CONCLUSIONS: Treatment of left-sided breast cancer in DIBH reduced dose to the heart and in most cases the lung dose, relative irradiated lung volume and lung mass. A mass related dosimetric benefit in DIBH can be achieved as long as the volume related benefit is about ≥8-9%. The lung expansion (breathing pattern) showed no impact on lung dose, but on heart dose. A stronger chest breathing (anterior expansion) for DIBH seems to be more beneficial than abdominal breathing.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。