Field-deployable, rapid diagnostic testing of saliva for SARS-CoV-2

可现场部署的唾液快速诊断检测 SARS-CoV-2

阅读:10
作者:Shan Wei #, Hemant Suryawanshi #, Alexandre Djandji, Esther Kohl, Stephanie Morgan, Eldad A Hod, Susan Whittier, Kevin Roth, Raymond Yeh, Juan Carlos Alejaldre, Elaine Fleck, Stephen Ferrara, Daniel Hercz, David Andrews, Lilly Lee, Kristopher A Hendershot, Joshua Goldstein, Yousin Suh, Mahesh Mansuk

Abstract

To safely re-open economies and prevent future outbreaks, rapid, frequent, point-of-need, SARS-CoV-2 diagnostic testing is necessary. However, existing field-deployable COVID-19 testing methods require the use of uncomfortable swabs and trained providers in PPE, while saliva-based methods must be transported to high complexity laboratories for testing. Here, we report the development and clinical validation of High-Performance Loop-mediated isothermal Amplification (HP-LAMP), a rapid, saliva-based, SARS-CoV-2 test with a limit of detection of 1.4 copies of virus per µl of saliva and a sensitivity and specificity with clinical samples of > 96%, on par with traditional RT-PCR based methods using swabs, but can deliver results using only a single fluid transfer step and simple heat block. Testing of 120 patient samples in 40 pools comprised of 5 patient samples each with either all negative or a single positive patient sample was 100% accurate. Thus, HP-LAMP may enable rapid and accurate results in the field using saliva, without need of a high-complexity laboratory.