Long-Term Changes in the Biomarkers of Left Atrial Fibrosis after Pulmonary Vein Isolation for Paroxysmal and Persistent Atrial Fibrillation

阵发性和持续性心房颤动肺静脉隔离术后左心房纤维化生物标志物的长期变化

阅读:7
作者:Lilla Szuromi, Orsolya Hajas, Edina Nagy-Baló, Ildikó N Forgács, László T Nagy, Miklós Fagyas, Attila Tóth, Béla Nagy Jr, János Kappelmayer, Zoltán Csanádi

Background

Atrial fibrillation (AF) is accompanied by inflammation and fibrosis to variable extent. The biomarkers of fibrosis were measured in patients with different forms of AF and cardiac status. Herein, we assessed the associations of the baseline concentrations of different biomarkers with the long-term success of pulmonary vein isolation (PVI) in patients with a structurally normal heart. Furthermore, we compared biomarker levels before and 3 years after ablation to gain further insights into the AF mechanism.

Conclusions

Our results demonstrated that the levels of CA-125, Caspase-3, Cathepsin L and Galectin-3 are not associated with AF recurrence after PVI in patients with a structurally normal heart and mainly paroxysmal AF. Except for CA-125, all the other biomarkers demonstrated a significant decrease during a 3-year follow-up post-ablation. Furthermore, Caspase-3 levels demonstrated a positive correlation with LA dimensions in patients with AF recurrence.

Methods

Patients, undergoing PVI for paroxysmal/persistent AF were enrolled prospectively. Blood samples were obtained 24 hours before and 3 years after ablation. Serum cancer antigen 125 (CA-125), plasma Caspase-3, Galectin-3 and Cathepsin L concentrations were measured. Follow-up visits every 6 months included 12-lead electrocardiogram, 24-hour Holter, trans-telephonic monitoring as well as transthoracic echocardiography after ablation. Biomarker levels, left ventricular ejection fraction and left atrial (LA) diameters at baseline and at the 3-year follow-up were compared in patients with versus without AF recurrence.

Results

A total of 63 patients were enrolled (23 women; age 61.4 ( ±<math><mo>±</mo></math> 8.8) years). The acute isolation of all pulmonary veins was achieved in all patients. During a mean follow-up of 36.3 ±<math><mo>±</mo></math> 6.3 months, AF recurrence was demonstrated in 26 (41.3%) patients. No significant differences were demonstrated in the levels of CA-125, Galectin-3, Caspase-3 and Cathepsin L pre- and post-ablation in patients with versus without AF recurrence. A significant decrease was detected in the concentrations of Caspase-3, Galectin-3 and Cathepsin L during follow-up with no difference in patients with versus without AF recurrence. A positive correlation was found between Caspase-3 levels and LA diameters in the AF recurrence group both before (r = 0.477; p = 0.018) and after the procedure (r = 0.533; p = 0.019). Conclusions: Our results demonstrated that the levels of CA-125, Caspase-3, Cathepsin L and Galectin-3 are not associated with AF recurrence after PVI in patients with a structurally normal heart and mainly paroxysmal AF. Except for CA-125, all the other biomarkers demonstrated a significant decrease during a 3-year follow-up post-ablation. Furthermore, Caspase-3 levels demonstrated a positive correlation with LA dimensions in patients with AF recurrence.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。