The accuracy of pleural ultrasonography in diagnosing complicated parapneumonic pleural effusions

胸膜超声在诊断复杂性肺炎旁胸腔积液中的准确性

阅读:1

Abstract

We compared the accuracy of pleural ultrasound versus chest CT versus chest radiograph (CXR) to determine radiographic complexity in predicting a complicated parapneumonic effusion (CPPE) defined by pleural fluid analysis. 66 patients with parapneumonic effusions were identified with complete data. Pleural ultrasound had a sensitivity of 69.2% (95% CI 48.2% to 85.7%) and specificity of 90.0% (95% CI 76.3% to 97.2%). Chest CT had a sensitivity of 76.9% (95% CI 56.3% to 91.0%) and specificity of 65.0% (95% CI 48.3% to 79.4%). CXR had a sensitivity of 61.5% (95% CI 40.6% to 79.8%) and specificity of 60.0% (95% CI 43.3% to 75.1%). Pleural ultrasound appears to be a superior modality to rule in a CPPE when compared with chest CT and CXR.