Biomechanical comparison of spinal column shortening - a finite element study

脊柱缩短的生物力学比较——有限元研究

阅读:1

Abstract

BACKGROUND: At present, research on spinal shortening is mainly focused on the safe distance of spinal shortening and the mechanism of spinal cord injury, but there is no research on the biomechanical characteristics of different shortening distances. The purpose of this study was to study the biomechanical characteristics of spine and internal fixation instruments at different shortening distances by the finite element (FE) method. METHODS: An FE model of lumbar L1-S was established and referred to the previous in vitro experiments to verify the rationality of the model by verifying the Intradiscal pressure (IDP) and the range of motion (ROM) of the motion segment. Five element models of spinal shortening were designed under the safe distance of spinal shortening, and the entire L3 vertebra and both the upper and lower intervertebral discs were resected. Model A was not shortened, while models B-E were shortened by 10%, 20%, 30% and 50% of the vertebral body, respectively. Constraining the ROM of the sacrum in all directions, a 7.5 N ·m moment and 280 N follower load were applied on the L1 vertebra to simulate the motion of the lumbar vertebrae in three planes. The ROM of the operated segments, the Von Mises stress (VMS) of the screw-rod system, the VMS of the upper endplate at the interface between the titanium cage and the L4 vertebral body, and the ROM and the IDP of the adjacent segment (L5/S) were recorded and analysed. RESULTS: All surgical models showed good stability at the operated segments (L1-5), with the greatest constraint in posterior extension (99.3-99.7%), followed by left-right bending (97.9-98.7%), and the least constraint in left-right rotation (84.9-86.3%) compared with the intact model. The VMS of the screw-rod system and the ROM and IDP of the distal adjacent segments of models A-E showed an increasing trend, in which the VMS of the screw-rod system of model E was the highest under flexion (172.5 MPa). The VMS of the endplate at the interface between the cage and L4 upper endplate of models A-E decreased gradually, and these trend were the most obvious in flexion, which were 3.03, 2.95, 2.83, 2.78, and 2.61 times that of the intact model, respectively. CONCLUSION: When performing total vertebrae resection and correcting the spinal deformity, if the corrected spine has met our needs, the distance of spinal shortening should be minimized to prevent spinal cord injury, fracture of internal fixations and adjacent segment disease (ASD).

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。