Liquid Low-Level Radioactive Waste Treatment Using an Electrodialysis Process

采用电渗析工艺处理液态低放射性废物

阅读:11
作者:Agnieszka Miśkiewicz, Agnieszka Nowak, Jędrzej Pałka, Grażyna Zakrzewska-Kołtuniewicz

Abstract

In this work, the possibility of using electrodialysis for the treatment of liquid low-level radioactive waste was investigated. The first aim of the research was to evaluate the influence of the process parameters on the treatment of model solutions with different compositions. Subsequent experimental tests were conducted using solutions containing selected radionuclides (60Co and 137Cs), which are potential contaminants of effluents from nuclear power plants, as well as components often found in waste generated from industrial and medical radioisotope applications. The results of the experiments performed on real radioactive waste confirmed that electrodialysis was a suitable method for the treatment of such effluents because it ensured high levels of desalination and rates of decontamination. The most important parameters impacting the process were the applied voltage and electrical current. Moreover, this research shows that the application of the ED process enables the separation of non-ionic organic contaminants of LLW, which are unfavorable in further stages of waste predisposal.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。