Effect Evaluation of Cardiac Resynchronization Therapy in Elderly Patients with Heart Failure by Ultrasound Image under QuickOpt Algorithm

基于QuickOpt算法的超声图像对老年心力衰竭患者心脏再同步治疗效果的评价

阅读:1

Abstract

This research was aimed at analyzing the application value of echocardiography and QuickOpt algorithm in optimizing parameters of cardiac resynchronization therapy (CRT) in elderly patients with heart failure. 50 elderly patients who were diagnosed with chronic heart failure and underwent CRT were chosen as the research objects. According to the different optimization methods, the patients were divided into the echocardiography group and QuickOpt algorithm group, 25 cases in each group. The general data, optimized intervals, corresponding maximum aortic velocity time integrals (aVTIs), cardiac ultrasound indicators, and ventricular arrhythmia episodes of the patients in the two groups were analyzed. The results showed that there was no significant difference in the optimized sensed atrioventricular (SAV), paced atrioventricular (PAV), and ventricle to ventricle (VV) intervals and the corresponding aVTIs obtained by echocardiography and QuickOpt (P > 0.05). The consistency analysis revealed that the aVTIs in the SAV, PAV, and VV intervals presented a good consistency (P < 0.01), which were obtained by the echocardiography and QuickOpt functional optimization; the concordance correlation coefficient (CCC) in them was 96.16%, 98.03%, and 95.48%, respectively. The left ventricular ejection fraction (LVEF) showed an increasing trend over time in both groups, while the left ventricular end systolic volume (LVESV), left ventricular end diastolic volume (LVEDV), and morphological right ventricle (MRV) showed the downward trends over time, and the differences between two groups were not significant (P > 0.05). For the premature ventricular contraction (PVC) of ventricular arrhythmia episodes, there was no significant difference between the two groups in log (PVCs) and log (PVC runs) (P > 0.05). It was also found that both echocardiography and QuickOpt algorithm could improve the cardiac function of patients with heart failure significantly and reduce ventricular arrhythmia episodes and ventricular remodeling via optimized CRT; there was no difference in the improvement effect of the two optimization methods. However, echocardiography was inferior to QuickOpt algorithm in terms of time-consuming optimization in the intervals. This provided a reference for the clinical diagnosis and treatment of elderly patients with heart failure.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。