Utility of the One-time HACOR Score as a Predictor of Weaning Failure from Mechanical Ventilation: A Prospective Observational Study

一次性HACOR评分作为机械通气撤机失败预测指标的效用:一项前瞻性观察研究

阅读:1

Abstract

AIM: To determine the utility of the HACOR score in predicting weaning failure in resource-limited settings. OBJECTIVES: The primary objective was to determine a cut-off value of the HACOR score, sensitivity, and specificity to predict failed weaning. The secondary objective was to determine which out of five components of the score was significantly different between the successful weaning and the failed weaning groups. INTRODUCTION: Most weaning indices are either inaccurate or are dependent on complex ventilatory parameters, which are difficult to measure in resource-limited settings. This study aimed to determine the utility of the HACOR score consisting of heart rate, acidosis, consciousness level, oxygenation, and respiratory rate as a predictor of weaning in the intensive care unit. MATERIALS AND METHODS: It was a prospective observational study on 120 patients between 18 and 90 years. The HACOR score was evaluated at 30 minutes of spontaneous breathing trial (SBT). The total duration of SBT was 120 minutes. RESULTS: Out of 120 patients, 83 (69.2%) had successful weaning, whereas 37 (30.8%) had weaning failure. The median and interquartile range (IQR) of the HACOR score in the successful weaning group was 2 (0-3) and 6 (5-8) in the failed weaning group (p-value <0.001). There was a significant difference in each of the five components of the HACOR score between the successful and failed weaning groups (p <0.05). HACOR score ≥5 predicted failed weaning, sensitivity 83.8%, specificity 96.4%, area under the curve (AUC) 0.950, and 95% confidence interval (CI) [0.907-0.993], p <0.001. Multivariable logistic regression analysis showed that HACOR score ≥5 is an independent predictor of weaning failure [p <0.001, 95% CI (1.9-4.2), adjusted odds ratio 2.82]. CONCLUSION: A HACOR score ≥5 is an excellent predictor of weaning failure. This score may be useful as a weaning strategy in the intensive care unit. HOW TO CITE THIS ARTICLE: Chaudhuri S, Gupta N, Adhikari SD, Todur P, Maddani SS, Rao S. Utility of the One-time HACOR Score as a Predictor of Weaning Failure from Mechanical Ventilation: A Prospective Observational Study. Indian J Crit Care Med 2022;26(8):900-905. ETHICAL APPROVAL: Prior to the commencement of the study, Institutional Ethics Committee permission was obtained (IEC: 197/2021) and Clinical Trial Registry of India (CTRI) registration was done before recruitment (CTRI/2021/07/035139). We obtained written informed consent from the legally authorized representative prior to recruiting patients for the study.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。