Comparison of the Efficacy of Different Arterial Waveform-derived Variables (Pulse Pressure Variation, Stroke Volume Variation, Systolic Pressure Variation) for Fluid Responsiveness in Hemodynamically Unstable Mechanically Ventilated Critically Ill Patients

比较不同动脉波形衍生变量(脉压变异、搏出量变异、收缩压变异)对血流动力学不稳定机械通气危重患者液体反应性的疗效

阅读:1

Abstract

INTRODUCTION: This study was conducted to assess fluid responsiveness in critically ill patients to avoid various complications of fluid overload. MATERIAL AND METHODS: This study was done in an ICU of a tertiary care hospital after approval from the institute ethical committee over 18 months. A total of 54 consenting adult patients were included in the study. Patients were hemodynamically unstable requiring mechanical ventilation, had acute circulatory failure, or those with at least one clinical sign of inadequate tissue perfusion. All patients were ventilated using tidal volume of 6-8 mL/kg, RR-12-15/minutes, positive end expiratory pressure (PEEP)-5 cm of water, and plateau pressure was kept below 30 cm water. They were sedated throughout the study. The arterial line and the central venous catheter were placed and connected to Vigileo-FloTrac transducer (Edward Lifesciences). Patients were classified into responder and nonresponder groups on the basis of the cardiac index (CI) after fluid challenge of 10 mL/kg of normal saline over 30 minutes. Pulse pressure variation (PPV), stroke volume variation (SVV), and systolic pressure variation (SPV) were assessed and compared at baseline, 30 minutes, and 60 minutes. RESULTS: In our study we found that PPV and SVV were significantly lower among responders than nonresponders at 30 minutes and insignificant at 60 minutes. Stroke volume variation was 10.28 ± 1.76 in the responder compared to 12.28 ± 4.42 (p = 0.02) at 30 minutes and PPV was 15.28 ± 6.94 in responders while it was 20.03 ± 4.35 in nonresponders (p = 0.01). We found SPV was insignificant at all time periods among both groups. CONCLUSION: We can conclude that initial assessment for fluid responsiveness in critically ill mechanically ventilated patients should be based on PPV and SVV to prevent complications of fluid overload and their consequences. HOW TO CITE THIS ARTICLE: Kumar N, Malviya D, Nath SS, Rastogi S, Upadhyay V. Comparison of the Efficacy of Different Arterial Waveform-derived Variables (Pulse Pressure Variation, Stroke Volume Variation, Systolic Pressure Variation) for Fluid Responsiveness in Hemodynamically Unstable Mechanically Ventilated Critically Ill Patients. Indian J Crit Care Med 2021;25(1):48-53.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。