Peripheral Doses Beyond Electron Applicators in Conventional C-Arm Linear Accelerators: A Systematic Literature Review

传统C型臂直线加速器中电子束照射器以外的周边剂量:系统性文献综述

阅读:1

Abstract

Background: This review investigates peripheral dose levels in electron beam treatments, comparing different manufacturers including Varian, Elekta, and Siemens. Accurate measurement of peripheral dose is vital for patient safety and precise radiation delivery in radiation therapy. Methods: This review followed PRISMA standards, conducting a comprehensive literature search from 1978 to July 2023. Emphasis was on identifying studies analyzing peripheral doses related to various electron beam energies, beam angle, field sizes, cutouts, and applicator combinations. Three major databases including PubMed, Web of Science, and Scopus were searched. Results: A total of 7 articles were included in this review. Strategies such as bolus materials, personalized cutouts, and optimal treatment procedures have all been developed to reduce peripheral radiation exposure and enhance patient safety. Ongoing research in this field is focused on further minimizing the risks associated with out-of-field radiation by improving dose delivery systems. Conclusion: The literature emphasizes importance of precision in electron beam radiation therapy, highlighting the critical need for managing peripheral doses and optimizing hardware to ensure patient safety. It advocates for the use of advanced tools and protocols to maintain a balance between effective treatment while protecting healthy tissues. Continuous research, careful treatment planning, and effective management of peripheral doses are essential.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。