Unilateral implantation of a new non-diffractive extended range-of-vision IOL in a young patient with Curschmann-Steinert myotonic dystrophy

在一名患有库尔施曼-施泰纳特肌强直性营养不良症的年轻患者中,单侧植入新型无衍射扩展视野人工晶状体

阅读:1

Abstract

PURPOSE: We present the case of a 36-year old Curschmann-Steinert myotonic dystrophy patient with posterior subcapsular cataract that we treated with unilateral implantation of an extended depth of focus intraocular lens to address his wish for spectacle independence at far and intermediate distance. OBSERVATIONS: The patient underwent phacoemulsification with subsequent implantation of the AcrySof IQ Vivity IOL (Alcon, Fort Worth, TX, USA) in his left eye. Uncorrected distance visual acuity (UDVA) on the left eye increased from +0.40 logMAR preoperatively to -0.12 logMAR at 3 months postoperatively. At the three months follow-up distance corrected intermediate visual acuity (DCIVA) at 80 cm distance was -0.08 logMAR and DCIVA at 66 cm distance was 0.14 logMAR for the left eye. The defocus curve showed a functional defocus of 2.0 diopters at 0.2 logMAR or better, corresponding to the extended depth of focus. Dysphotopsia evaluation with a Halo & Glare simulator (Eyeland-Design Network GmbH, Vreden, Germany) revealed a very low level of photic phenomena. CONCLUSIONS AND IMPORTANCE: Unilateral implantation of a new generation, non-diffractive extended depth of focus IOL was well tolerated and provided good functional results for far and intermediate distances. The patient reported a very low level of photic phenomena.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。