Detection and classification of breast lesions using multiple information on contrast-enhanced mammography by a multiprocess deep-learning system: A multicenter study

利用多过程深度学习系统,结合对比增强乳腺X线摄影的多重信息进行乳腺病变的检测和分类:一项多中心研究

阅读:1

Abstract

OBJECTIVE: Accurate detection and classification of breast lesions in early stage is crucial to timely formulate effective treatments for patients. We aim to develop a fully automatic system to detect and classify breast lesions using multiple contrast-enhanced mammography (CEM) images. METHODS: In this study, a total of 1,903 females who underwent CEM examination from three hospitals were enrolled as the training set, internal testing set, pooled external testing set and prospective testing set. Here we developed a CEM-based multiprocess detection and classification system (MDCS) to perform the task of detection and classification of breast lesions. In this system, we introduced an innovative auxiliary feature fusion (AFF) algorithm that could intelligently incorporates multiple types of information from CEM images. The average free-response receiver operating characteristic score (AFROC-Score) was presented to validate system's detection performance, and the performance of classification was evaluated by area under the receiver operating characteristic curve (AUC). Furthermore, we assessed the diagnostic value of MDCS through visual analysis of disputed cases, comparing its performance and efficiency with that of radiologists and exploring whether it could augment radiologists' performance. RESULTS: On the pooled external and prospective testing sets, MDCS always maintained a high standalone performance, with AFROC-Scores of 0.953 and 0.963 for detection task, and AUCs for classification were 0.909 [95% confidence interval (95% CI): 0.822-0.996] and 0.912 (95% CI: 0.840-0.985), respectively. It also achieved higher sensitivity than all senior radiologists and higher specificity than all junior radiologists on pooled external and prospective testing sets. Moreover, MDCS performed superior diagnostic efficiency with an average reading time of 5 seconds, compared to the radiologists' average reading time of 3.2 min. The average performance of all radiologists was also improved to varying degrees with MDCS assistance. CONCLUSIONS: MDCS demonstrated excellent performance in the detection and classification of breast lesions, and greatly enhanced the overall performance of radiologists.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。