Nonmalignant breast lesions: ADCs of benign and high-risk subtypes assessed as false-positive at dynamic enhanced MR imaging

非恶性乳腺病变:在动态增强磁共振成像中,良性和高危亚型的ADC值被评估为假阳性

阅读:1

Abstract

PURPOSE: To evaluate the diffusion-weighted (DW) imaging characteristics of nonmalignant lesion subtypes assessed as false-positive findings at conventional breast magnetic resonance (MR) imaging. MATERIALS AND METHODS: This HIPAA-compliant retrospective study had institutional review board approval, and the need for informed patient consent was waived. Lesions assessed as Breast Imaging Reporting and Data System category 4 or 5 at clinical dynamic contrast material-enhanced MR imaging that subsequently proved nonmalignant at biopsy were retrospectively reviewed. One hundred seventy-five nonmalignant breast lesions in 165 women were evaluated. Apparent diffusion coefficients (ADCs) from DW imaging (b = 0, 600 sec/mm(2)) were calculated for each lesion and were compared between subtypes and with an ADC threshold of 1.81 × 10(-3) mm(2)/sec (determined in a prior study to achieve 100% sensitivity). RESULTS: Eighty-one (46%) lesions exhibited ADCs greater than the predetermined threshold. The most prevalent lesion subtypes with mean ADCs above the threshold were fibroadenoma ([1.94 ± 0.38 {standard deviation}] × 10(-3) mm(2)/sec; n = 30), focal fibrosis ([1.84 ± 0.48] × 10(-3) mm(2)/sec; n = 19), normal tissue ([1.81 ± 0.47] × 10(-3) mm(2)/sec; n = 13), apocrine metaplasia ([2.01 ± 0.38] × 10(-3) mm(2)/sec; n = 13), usual ductal hyperplasia ([1.83 ± 0.49] × 10(-3) mm(2)/sec; n = 12), and inflammation ([1.95 ± 0.46] × 10(-3) mm(2)/sec; n = 10). Atypical ductal hyperplasia ([1.48 ± 0.36] × 10(-3) mm(2)/sec; n = 23) was the most common lesion subtype with ADC below the threshold. Lymph nodes exhibited the lowest mean ADC of all nonmalignant lesions ([1.28 ± 0.23] × 10(-3) mm(2)/sec; n = 4). High-risk lesions (atypical ductal hyperplasia and lobular neoplasia) showed significantly lower ADCs than other benign lesions (P < .0001) and were the most common lesions with ADCs below the threshold. CONCLUSION: Assessing ADC along with dynamic contrast-enhanced MR imaging features may decrease the number of avoidable false-positive findings at breast MR imaging and reduce the number of preventable biopsies. The ability of DW imaging to help differentiate high-risk lesions requiring additional work-up from other nonmalignant subtypes may further improve patient care. SUPPLEMENTAL MATERIAL: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.12112672/-/DC1.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。