Accuracy of Synovial Leukocyte and Polymorphonuclear Cell Count in Patients with Shoulder Prosthetic Joint Infection

肩关节假体感染患者滑膜白细胞和多形核细胞计数的准确性

阅读:1

Abstract

Joint aspiration in suspected infected implants is a validated diagnostic method in establishing the diagnosis of prosthetic joint infection (PJI). Cut-off values for synovial leukocyte counts and differentials are well described for patients with hip and knee PJI. In 19 failed shoulder implants, a leucocyte count of >12.2 G/L had a sensitivity and specificity of 92% and 100% respectively; A differential of >54% neutrophils had a sensitivity of 100 % and a specificity of 75%.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。