A rapid test for the environmental detection of pigeon antigen

环境鸽抗原快速检测方法

阅读:12
作者:Silvia Sánchez-Díez, María-Jesús Cruz, Daniel Álvarez-Simón, Tomás Montalvo, Xavier Muñoz, Peter M Hoet, Jeroen A Vanoirbeek, Susana Gómez-Ollés

Conclusions

Since there was a good correlation between both assays, we can conclude that the rapid and simple ICT assay is a good and valid alternative, which does not require expensive equipment, for the validated ELISA technique.

Methods

An amplified sandwich ELISA using pigeon serum as a calibration standard and a ICT using gold-labeled anti-pigeon serum antibodies for the rapid detection of pigeon antigens in environmental samples were developed. Twenty-two different airborne samples were collected and analysed using both methods. Strip density values obtained with ICT were calculated and compared with the concentrations determined by the ELISA method for pigeon antigens. Strips

Results

The ELISA method to quantify pigeon antigen had a broader range (58.4 and 10,112.2 ng/ml), compared to the ICT assay (420 to 3360 ng/ml). A kappa index of 0.736 (p < 0.0001) was obtained between the observers evaluating the ICT strips. The results of the ELISA and the relative density of the ICT showed a highly significant correlation (rs:0.935; p < 0.0001). Bland-Altman plot also confirmed excellent agreement between the two methods (mean difference: -1.626; p < 0.0001). Conclusions: Since there was a good correlation between both assays, we can conclude that the rapid and simple ICT assay is a good and valid alternative, which does not require expensive equipment, for the validated ELISA technique.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。