Efficient method for whole-breast irradiation therapy using Halcyon linear accelerators

利用Halcyon直线加速器进行全乳放射治疗的有效方法

阅读:1

Abstract

BACKGROUND: The Halcyon is a linear accelerator-based treatment machine designed for a high-throughput simplified workflow. The machine features a compact jawless design, dual-layer multileaf collimators, and a single 6-MV flattening filter-free (FFF) beam. However, the machine's 6-MV FFF beam may restrict its applicability to conventional techniques, such as field-in-field (FiF) radiotherapy, for breast cancer treatment. This study developed a practical and efficient hybrid method for imaging, planning, and irradiation procedures for whole-breast irradiation using Halcyon linear accelerators. MATERIALS AND METHODS: The proposed method involves five major steps: (1) field arrangement, (2) planning target volume (PTV) generation and evaluation, (3) basal plan generation, (4) inverse planning intensity-modulated radiation therapy plan generation, and (5) plan evaluation and irradiation. The PTV is generated using isodose curves plotted on the basis of tangential fields, which are applied to create a basal plan. Subsequently, a basal-dose-compensation approach is applied to further optimize the treatment plan. This efficient workflow necessitates executing only one onboard cone-beam computed tomography procedure. This study included 10 patients with early-stage breast cancer who were treated at our center. The performance of the proposed method was evaluated by comparing its corresponding irradiation time and dose statistics with those derived for a dynamically flattened beam-based FiF (DFB-FiF) method. RESULTS: All plans were normalized to ensure that 98% of the prescribed dose covered 95% of the PTV. On average, the global maximum doses in the proposed and DFB-FiF methods were lower than 106%. The homogeneity index for right-sided (left-sided) breast cancer was 0.053 (0.056) in the proposed method and 0.073 (0.076) in the DFB-FiF method. The dose statistics of normal tissues, including the contralateral breast, heart, and lungs, were comparable between the methods. However, the irradiation time per monitor unit in the proposed method was approximately five times faster than that in the DFB-FiF method, but the planning time and complexity were similar between the methods. CONCLUSIONS: This study developed and evaluated an efficient and practical hybrid method for whole-breast irradiation using the Halcyon. This method can significantly reduce the irradiation time, while providing comparable dose statistics to the DFB-FiF method.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。