Model refinement increases confidence levels and clinical agreement when commissioning a three-dimensional secondary dose calculation system

模型改进提高了三维二次剂量计算系统的调试过程中的置信度和临床一致性。

阅读:1

Abstract

PURPOSE: Evaluate custom beam models for a second check dose calculation system using statistically verifiable passing criteria for film analysis, DVH, and 3D gamma metrics. METHODS: Custom beam models for nine linear accelerators for the Sun Nuclear Dose Calculator algorithm (SDC, Sun Nuclear) were evaluated using the AAPM-TG119 test suite (5 Intensity Modulated Radiation Therapy (IMRT) and 5 Volumetric Modulated Arc Therapy (VMAT) plans) and a set of clinical plans. Where deemed necessary, adjustments to Multileaf Collimator (MLC) parameters were made to improve results. Comparisons to the Analytic Anisotropic Algorithm (AAA), and gafchromic film measurements were performed. Confidence intervals were set to 95% per TG-119. Film gamma criteria were 3%/3 mm (conventional beams) or 3%/1 mm (Stereotactic Radiosurgery [SRS] beams). Dose distributions in solid water phantom were evaluated based on DVH metrics (e.g., D95, V20) and 3D gamma criteria (3%/3 mm or 3%/1 mm). Film passing rates, 3D gamma passing rates, and DVH metrics were reported for HD MLC machines and Millennium MLC Machines. RESULTS: For HD MLC machines, SDC gamma film agreement was 98.76% ± 2.30% (5.74% CL) for 6FFF/6srs (3%/1 mm), and 99.80% ± 0.32% (0.83% CL) for 6x (3%/3 mm). For Millennium MLC machines, film passing rates were 98.20% ± 3.14% (7.96% CL), 99.52% ± 1.14% (2.71% CL), and 99.69% ± 0.82% (1.91% CL) for 6FFF, 6x, and 10x, respectively. For SDC to AAA comparisons: HD MLC Linear Accelerators (LINACs); DVH point agreement was 0.97% ± 1.64% (4.18% CL) and 1.05% ± 2.12% (5.20% CL); 3D gamma agreement was 99.97% ± 0.14% (0.30% CL) and 100.00% ± 0.02% (0.05% CL), for 6FFF/6srs and 6x, respectively; Millennium MLC LINACs: DVH point agreement was 0.77% ± 2.40% (5.47% CL), 0.80% ± 3.40% (7.47% CL), and 0.07% ± 2.15% (4.30% CL); 3D gamma agreement was 99.97% ± 0.13% (0.29% CL), 99.97% ± 0.17% (0.36% CL), and 99.99% ± 0.06% (0.12% CL) for 6FFF, 6x, and 10x, respectively. CONCLUSION: SDC shows agreement well within TG119 CLs for film and redundant dose calculation comparisons with AAA. In some models (SRS), this was achieved using stricter criteria. TG119 plans can be used to help guide model adjustments and to establish clinical baselines for DVH and 3D gamma criteria.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。