Intensity-modulated radiation therapy for multiple targets with tomotherapy using multiple sets of static ports from different angles

利用多组静态照射野从不同角度进行多靶点调强放射治疗

阅读:1

Abstract

BACKGROUND: To treat multiple targets separated in the craniocaudal direction within a short time, we invented a new technique using multiple static-port tomotherapy with the dynamic-jaw mode and named it the pseudo-DJDC (pDJDC) technique. We compared the pDJDC plans and helical tomotherapy plans using the dynamic-jaw mode (HDJ) for multiple targets. In the pDJDC plans, we used a beam set with 2-7 ports to the targets at the same level in the craniocaudal direction, and employed another beam set for other targets using different port angles (9-12 angles in total). METHODS: In seven patients, two plans using the pDJDC and HDJ techniques were compared. For multiple targets (n = 2-6), 20-60 Gy in 2- to 7.5-Gy fractions were prescribed for the planning target volumes at D50%. The conformity index, uniformity index (D5%/D95%), dose distribution in the lung, and treatment time were evaluated. RESULTS: The median conformity index of all seven patients was 3.0 for the pDJDC plans and 2.4 for the HDJ plans (P = 0.031). The median uniformity indices of the planning target volume (n = 25) for the two plans were 1.048 and 1.057, respectively (P = 0.10). For five patients with thoracic targets, the median mean lung doses were 2.6 Gy and 2.4 Gy, respectively (P = 0.63). The median V5Gy and V20Gy of the lungs in the five patients were 11.8% and 8.5% (P = 0.63), and 1.6% and 2.1% (P = 0.31), respectively. The pDJDC plans reduced the treatment time by 48% compared to the HDJ plans (median: 462 and 884 sec, respectively, P = 0.031). CONCLUSION: The pDJDC technique allows treatment of multiple targets in almost half the time of the HDJ technique. The pDJDC plans were comparable to the HDJ plans in dose distribution, although the conformity index deteriorated.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。