Going the distance: validation of Acuros and AAA at an extended SSD of 400 cm

超长距离测试:Acuros 和 AAA 在 400 厘米超长 SSD 下的验证

阅读:1

Abstract

Accurate dose calculation and treatment delivery is essential for total body irradiation (TBI). In an effort to verify the accuracy of TBI dose calculation at our institution, we evaluated both the Varian Eclipse AAA and Acuros algorithms to predict dose distributions at an extended source-to-surface distance (SSD) of 400 cm. Measurements were compared to calculated values for a 6 MV beam in physical and virtual phantoms at 400 cm SSD using open beams for both 5 × 5 and 40 × 40cm2 field sizes. Inline and crossline profiles were acquired at equivalent depths of 5 cm, 10 cm, and 20 cm. Depth-dose curves were acquired using EBT2 film and an ion chamber for both field sizes. Finally, a RANDO phantom was used to simulate an actual TBI treatment. At this extended SSD, care must be taken using the planning system as there is good relative agreement between measured and calculated profiles for both algorithms, but there are deviations in terms of the absolute dose. Acuros has better agreement than AAA in the penumbra region.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。