Three-dimensional dynamic contrast enhanced imaging of the carotid artery with direct arterial input function measurement

利用三维动态对比增强成像技术直接测量颈动脉的动脉输入函数

阅读:1

Abstract

PURPOSE: Kinetic analysis using dynamic contrast enhanced MRI to assess neovascularization of carotid plaque requires images with high spatial and temporal resolution. This work demonstrates a new three-dimensional (3D) dynamic contrast enhanced imaging sequence, which directly measures the arterial input function with high temporal resolution yet maintains the high spatial resolution required to identify areas of increased adventitial neovascularity. THEORY AND METHODS: The sequence consists of multiple rapid acquisitions of a saturation prepared dynamic 3D gradient recalled echo (GRE) sequence temporally interleaved with multiple acquisitions of a 2D slice. The saturation recovery time was adjusted to maintain signal linearity with the very different contrast agent concentrations in the 2D slice and 3D volume. The K(trans) maps were obtained from the 3D dynamic contrast measurements while the 2D slice was used to obtain the arterial input function. Calibration and dynamic studies are presented. RESULTS: For contrast agent concentrations up to 5 mM, a saturation recovery time for the 2D slice of 20 ms resulted in less than a 10% deviation from the desired linear response of signal intensity with contrast agent concentration. The corresponding saturation recovery time of 83 ms for the 3D volume maintained less than a 10% deviation from the linear response up to contrast agent concentrations of 2 mM while a contrast agent concentration of 5 mM had almost a 30% deviation. There was a significant improvement in signal attenuation (9 ± 3% versus 23 ± 5% at 40 cm/s) when flow compensation was added to the slice select gradients. For patient studies, volume transfer and plasma fraction maps were calculated with data from the proposed sequence. CONCLUSION: This work demonstrated a novel sequence for 3D dynamic contrast enhanced imaging with a simultaneously acquired 2D slice that directly measures the arterial input function with high temporal resolution. Acquisition parameters can be adjusted to accommodate the full range of contrast agent concentration values to be encountered and the kinetic parameters obtained were consistent with expected values.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。