The Effect of Mechanically-Generated Vibrations on the Efficacy of Hemodialysis; Assessment of Patients' Safety: Preliminary Reports

机械振动对血液透析疗效的影响;患者安全性评估:初步报告

阅读:1

Abstract

Muscle activity during a hemodialysis procedure improves its efficacy. We have formulated a hypothesis that vibrations generated by a specially-designed dialysis chair can, the same as physical exercise, affect the filtering of various fluids between fluid spaces during the hemodialysis procedure. This prospective and interventional study included 21 dialyzed patients. During a single dialysis session, each patient used a prototype device with the working name "vibrating chair". The chair's drive used a low-power cage induction motor, which, along with the worm gear motor, was a part of the low-frequency (3.14 Hz) vibration-generating assembly with an amplitude of 4 mm. Tests and measurements were performed before and after the vibration dialysis. After a single hemodialysis session including five 3-min cycles of vibrations, an increase in K t / V in relation to non-vibration K t / V ( 1.53 ± 0.26 vs. 1.62 ± 0.23 ) was seen. Urea reduction ratio increased significantly ( 0.73 ± 0.03 vs. 0.75 ± 0.03 ). A significant increase in systolic blood pressure was observed between the first and the third measurement ( 146 ± 18 vs. 156 ± 24 ). The use of a chair generating low-frequency vibrations increased dialysis adequacy; furthermore, it seems an acceptable and safe alternative to intradialytic exercise.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。