Reliability and minimal detectable difference of pressure pain thresholds in a pain-free population

无痛人群中压力痛阈值的可靠性和最小可检测差异

阅读:1

Abstract

The objective of this work was to evaluate the inter-rater and intra-rater reliability and minimal detectable difference (MDD) of pressure pain thresholds (PPTs) in pain-free participants with two examiners over two consecutive days in a cross-sectional study design. Examiners used a standardized method to measure and locate a specific testing site over tibialis anterior for PPT testing with a hand-held algometer. The mean of each examiner's three PPT measurements was used to calculate the intraclass correlation coefficient, inter-rater reliability, and intra-rater reliability. The minimal detectable difference (MDD) was calculated. Eighteen participants were recruited (11 female). The inter-rater reliability was 0.94 and 0.96 on day 1 and day 2, respectively. Intra-rater reliability for the examiners was 0.96 and 0.92 on day 1 and day 2, respectively. The MDD on day 1 was 1.24 kg/cm(2) (CI: 0.76-2.03) and the MDD on day 2 was 0.88 kg/cm(2) (CI: 0.54-1.43). This study demonstrates high inter- and intra-rater reliability and the MDD values for this method of pressure algometry.