Analysis of Membrane Behavior of a Normally Closed Microvalve Using a Fluid-Structure Interaction Model

利用流固耦合模型分析常闭式微阀的膜行为

阅读:1

Abstract

In this paper, membrane deflection against fluid flow and opening membrane (threshold) pressure were studied using fluid-structure interaction (FSI) analysis, and compared with experimental data obtained by Jaemin et al. In the current analysis, two different models (I-shaped and V-shaped) were used to perform the FSI simulation. In microvalve modeling, in order to reduce external actuator usage, interconnections are made between two similar microvalves. This typical interconnection creates a pressure distribution in a local environment. Furthermore, to differentiate the volume factor in a microvalve, a length/width (L/W) ratio term was used. Compared with higher- and lower-L/W-ratio models, the higher-L/W model eventually initiates more deflection in a low-pressure regime than the lower-L/W-ratio model. FSI simulations were performed for 4 μL/min, 6 μL/min, 8 μL/min, 10 μL/min, and 12 μL/min flow rates against membrane behavior, and performance evaluations of the microvalves were conducted. It was observed during an FSI simulation that the gate pressure applied to the lower surface deflects the membrane upward, thereby making contact with the wall. Two important parameters (material properties of the structural membrane and the inlet region height) were selected for analysis to evaluate changes in microvalve performance. These results are presented in the current study.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。