Ability of laboratories to detect emerging antimicrobial resistance: proficiency testing and quality control results from the World Health Organization's external quality assurance system for antimicrobial susceptibility testing

实验室检测新出现的抗菌药物耐药性的能力:世界卫生组织抗菌药物敏感性测试外部质量保证体系的能力验证和质量控制结果

阅读:1

Abstract

The accuracy of antimicrobial susceptibility data submitted by microbiology laboratories to national and international surveillance systems has been debated for a number of years. To assess the accuracy of data submitted to the World Health Organization by users of the WHONET software, the Centers for Disease Control and Prevention distributed six bacterial isolates representing key antimicrobial-resistance phenotypes to approximately 130 laboratories, all but one of which were outside of the United States, for antimicrobial susceptibility testing as part of the World Health Organization's External Quality Assurance System for Antimicrobial Susceptibility Testing. Each laboratory also was asked to submit 10 consecutive quality control values for several key organism-drug combinations. Most laboratories were able to detect methicillin (oxacillin) resistance in Staphylococcus aureus, high-level vancomycin resistance in Enterococcus faecium, and resistance to extended-spectrum cephalosporins in Klebsiella pneumoniae. Many laboratories, particularly those using disk diffusion tests, had difficulty in recognizing reduced susceptibility to penicillin in an isolate of Streptococcus pneumoniae. The most difficult phenotype for laboratories to detect was reduced susceptibility to vancomycin in an isolate of Staphylococcus epidermidis. The proficiency testing challenge also included a request for biochemical identification of a gram-negative bacillus, which most laboratories recognized as Enterobacter cloacae. Although only a small subset of laboratories have submitted their quality control data, it is clear that many of these laboratories generate disk diffusion results for oxacillin when testing S. aureus ATCC 25923 and S. pneumoniae ATCC 49619 that are outside of the acceptable quality control range. The narrow quality control range for vancomycin also proved to be a challenge for many of the laboratories submitting data; approximately 27% of results were out of range. Thus, it is important to establish the proficiency of laboratories submitting data to surveillance systems in which the organisms are tested locally, particularly for penicillin resistance in pneumococci and glycopeptide resistance in staphylococci.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。