Is plasma amyloid-β 1-42/1-40 a better biomarker for Alzheimer's disease than AβX-42/X-40?

血浆淀粉样蛋白-β 1-42/1-40 是否比 AβX-42/X-40 更能成为阿尔茨海默病的生物标志物?

阅读:16
作者:Hans-Wolfgang Klafki, Barbara Morgado, Oliver Wirths, Olaf Jahn, Chris Bauer, Hermann Esselmann, Johannes Schuchhardt, Jens Wiltfang

Background

A reduced amyloid-β (Aβ)42/40 peptide ratio in blood plasma represents a peripheral biomarker of the cerebral amyloid pathology observed in Alzheimer's disease brains. The magnitude of the measurable effect in plasma is smaller than in cerebrospinal fluid, presumably due to dilution by Aβ peptides originating from peripheral sources. We hypothesized that the observable effect in plasma can be accentuated to some extent by specifically measuring Aβ1-42 and Aβ1-40 instead of AβX-42 and AβX-40.

Conclusions

Our findings support the hypothesis that the relatively small difference in the plasma Aβ42/40 ratio between subjects with and without evidence of brain amyloidosis can be accentuated by specifically measuring Aβ1-42/1-40 instead of AβX-42/X-40. A simplified theoretical model explaining this observation is presented.

Methods

We assessed the plasma AβX-42/X-40 and Aβ1-42/1-40 ratios in an idealized clinical sample by semi-automated Aβ immunoprecipitation followed by closely related sandwich immunoassays. The amyloid-positive and amyloid-negative groups (dichotomized according to Aβ42/40 in cerebrospinal fluid) were compared regarding the median difference, mean difference, standardized effect size (Cohen's d) and receiver operating characteristic curves. For statistical evaluation, we applied bootstrapping.

Results

The median Aβ1-42/1-40 ratio was 20.86% lower in amyloid-positive subjects than in the amyloid-negative group, while the median AβX-42/X-40 ratio was only 15.56% lower. The relative mean difference between amyloid-positive and amyloid-negative subjects was -18.34% for plasma Aβ1-42/1-40 compared to -15.50% for AβX-42/X-40. Cohen's d was 1.73 for Aβ1-42/1-40 and 1.48 for plasma AβX-42/X-40. Unadjusted p-values < 0.05 were obtained after .632 bootstrapping for all three parameters. Receiver operating characteristic analysis indicated very similar areas under the curves for plasma Aβ1-42/1-40 and AβX-42/X-40. Conclusions: Our findings support the hypothesis that the relatively small difference in the plasma Aβ42/40 ratio between subjects with and without evidence of brain amyloidosis can be accentuated by specifically measuring Aβ1-42/1-40 instead of AβX-42/X-40. A simplified theoretical model explaining this observation is presented.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。