Feasibility of magnetic bead technology for concentration of mycobacteria in sputum prior to fluorescence microscopy

利用磁珠技术浓缩痰液中分枝杆菌进行荧光显微镜检查的可行性

阅读:2

Abstract

BACKGROUND: Direct sputum smear microscopy is the mainstay of TB diagnosis in most low and middle income countries, and is highly specific for Mycobacterium tuberculosis in such settings. However it is limited by low sensitivity, particularly in HIV co-infected patients. Concentration by centrifugation has been reported to be more sensitive than direct smear preparation, but is only suitable for referral laboratories. Simpler concentration methods that could be applied in peripheral laboratories are urgently needed. METHODS: We evaluated the feasibility of an early prototype ligand-coated magnetic bead technology to concentrate M. tuberculosis prior to detection by LED-based fluorescence microscopy compared with direct Ziehl-Neelsen microscopy and direct and concentrated fluorescence microscopy in a reference laboratory in Kampala, Uganda. Results were compared with MGIT 960 liquid culture and Lowenstein-Jensen culture. RESULTS: Compared to culture, concentrated FM had significantly higher sensitivity than direct ZN (74.8% and 51.4%), magnetic bead-FM (65.4%) and direct FM (58.9%). The sensitivity of magnetic bead FM was significantly higher than direct ZN (p<0.001) but not significantly higher than direct FM (p=0.210). The specificity of magnetic bead FM and concentrated FM was significantly lower than direct ZN (88.6%, 94.3% and 98.9% respectively) and direct FM (99.4%). There was no significant difference in specificity between magnetic bead FM and concentrated FM. Allowing for blinded resolution of discrepant results, the specificity of magnetic bead FM increased to 93.1%. Direct microscopy was simpler than concentrated FM and Magnetic bead FM which both had a similar number of steps. CONCLUSION: The sensitivity of the early prototype magnetic bead FM was lower than concentrated FM, similar to direct FM, and significantly higher than direct ZN. Both magnetic bead and concentration by centrifugation led to reduced specificity compared with the direct smear methods. Some magnetic bead FM false positive results were not easily explained and should be further investigated. The prototype version of the magnetic bead procedure tested here was of similar complexity to concentration by centrifugation. As such, if the sensitivity of the magnetic bead FM could be improved in future versions of the technology, this may offer a viable alternative to centrifugation.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。