Abstract

PURPOSE: To compare hemodynamic effects of two different modes of ventilation (volume-controlled and pressure-controlled volume guaranteed) in patients undergoing laparoscopic gynecology surgeries with exaggerated Trendelenburg position. METHODS: Thirty patients undergoing laparoscopic gynecology operations were ventilated using either volume-controlled (Group VC) or pressure-controlled volume guaranteed mode (Group PCVG) (n = 15 for both groups). Hemodynamic variables were measured using Pressure Recording Analytical Method by radial artery cannulation in addition to peak and mean airway pressures and expired tidal volume. RESULTS: The only remarkable finding was a more stable cardiac index in Group PCVG, where other hemodynamic parameters were similar. Expired tidal volume increased in Group VC while peak airway pressure was lower in Group PCVG. CONCLUSION: PCV-VG causes less hemodynamic perturbations as measured by Pressure Recording Analytical Method (PRAM) and allows better intraoperative hemodynamic control in exaggerated Trendelenburg position in laparoscopic surgery.