Simultaneous Measurement of Refractive Index and Temperature Based on SMF-HCF-FCF-HCF-SMF Fiber Structure

基于SMF-HCF-FCF-HCF-SMF光纤结构的折射率和温度同时测量

阅读:9
作者:Ronghui Xu, Chengran Ke, Yipu Xue, Yifei Xu, Minmin Xue, Jingfu Ye, Houquan Liu, Ming Chen, Shiliang Qu, Libo Yuan

Abstract

In this research, we proposed and experimentally verified a compact all-fiber sensor that can measure refractive index (RI) and temperature simultaneously. Two segments of hollow-core fiber (HCF) are connected to the two ends of the four-core fiber (FCF) as a beam splitter and a coupler, and then spliced with two sections of single-mode fibers (lead-in and lead-out SMF), respectively. The two hollow-core fibers can excite the higher-order modes of the four-core fiber and recouple the core modes and higher-order modes into the outgoing single-mode fiber, thereby forming inter-mode interference. The different response sensitivities of two interference dips to RI and temperature manifest that the proposed structure can achieve simultaneous measurement. From the experimental results, it can be seen that the maximum sensitivity of the sensor to RI and temperature is 275.30 nm/RIU and 94.4 pm/°C, respectively. When the wavelength resolution is 0.02 nm, the RI and temperature resolutions of the sensor are 7.74 × 10-5 RIU and 0.335 °C. The proposed dual-parameter optical sensor has the advantages of high sensitivities, good repeatability, simple fabrication, and structure. In addition, it has potential application value in multi-parameter simultaneous measurement.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。