A novel polyclonal antibody-based sandwich ELISA for detection of Plasmodium vivax developed from two lactate dehydrogenase protein segments

一种基于多克隆抗体的新型夹心ELISA方法,用于检测间日疟原虫,该方法由两个乳酸脱氢酶蛋白片段开发而成。

阅读:1

Abstract

BACKGROUND: Immunoassays for Plasmodium detection are, presently, most frequently based on monoclonal antibodies (MAbs); Polyclonal antibodies (PAbs), which are cheaper to develop and manufacture, are much less frequently used. In the present study we describe a sandwich ELISA assay which is capable of detecting P. vivax Lactate Dehydrogenase (LDH) in clinical blood samples, without cross reacting with those infected with P. falciparum. METHODS: Two recombinant proteins were produced from different regions of the P. vivax LDH gene. Two sandwich ELISA assay were then designed: One which uses mouse anti-LDH 1-43aa PAbs as primary antibodies ("Test 1") and another which uses anti-LDH 35-305aa PAbs ("Test 2") as the primary antibodies. Rabbit anti-LDH 1-43aa PAbs were used as capture antibodies in both ELISA assays. Blood samples taken from P. vivax and P. falciparum infected patients (confirmed by light microscopy) were analysed using both tests. RESULTS: "Test 2" performed better at detecting microscopy-positive blood samples when compared to "Test 1", identifying 131 of 154 positive samples (85%); 85 positives (55%) were identified using "test 1". "Test 1" produced one false positive sample (from the 20 malaria-free control) blood samples; "test 2" produced none. Kappa coefficient analysis of the results produced a value of 0.267 when microscope-positive blood smears were compared with "test 1", but 0.734 when microscope-positive blood smears were compared with the results from "test 2". Positive predictive value (PPV) and negative predictive value (NPV) were observed to be 98% and 22% respectively, for "Test 1", and 99% and 45%, for "test 2". No cross reactivity was detected with P. falciparum positive blood samples (n = 15) with either test assay. CONCLUSION: Both tests detected P. vivax infected blood and showed no evidence of cross-reacting with P. falciparum. Further studies will need to be conducted to establish the full potential of this technique for malaria diagnostics. As well as representing a promising new cost-effective novel technique for P. vivax diagnosis and research, the method for developing this assay also highlights the potential for PAb-based strategies for diagnostics in general.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。