Evaluating Diagnostic Accuracy and Inter-reader Agreement of the Prostate Imaging After Focal Ablation Scoring System

评估前列腺局部消融术后影像评分系统的诊断准确性和阅片者间一致性

阅读:1

Abstract

BACKGROUND AND OBJECTIVE: Focal therapy (FT) is increasingly recognized as a promising approach for managing localized prostate cancer (PCa), notably reducing treatment-related morbidities. However, post-treatment anatomical changes present significant challenges for surveillance using current imaging techniques. This study aimed to evaluate the inter-reader agreement and efficacy of the Prostate Imaging after Focal Ablation (PI-FAB) scoring system in detecting clinically significant prostate cancer (csPCa) on post-FT multiparametric magnetic resonance imaging (mpMRI). METHODS: A retrospective cohort study was conducted involving patients who underwent primary FT for localized csPCa between 2013 and 2023, followed by post-FT mpMRI and a prostate biopsy. Two expert genitourinary radiologists retrospectively evaluated post-FT mpMRI using PI-FAB. The key measures included inter-reader agreement of PI-FAB scores, assessed by quadratic weighted Cohen's kappa (κ), and the system's efficacy in predicting in-field recurrence of csPCa, with a PI-FAB score cutoff of 3. Additional diagnostic metrics including sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and overall accuracy were also evaluated. KEY FINDINGS AND LIMITATIONS: Scans from 38 patients were analyzed, revealing a moderate level of agreement in PI-FAB scoring (κ = 0.56). Both radiologists achieved sensitivity of 93% in detecting csPCa, although specificity, PPVs, NPVs, and accuracy varied. CONCLUSIONS AND CLINICAL IMPLICATIONS: The PI-FAB scoring system exhibited high sensitivity with moderate inter-reader agreement in detecting in-field recurrence of csPCa. Despite promising results, its low specificity and PPV necessitate further refinement. These findings underscore the need for larger studies to validate the clinical utility of PI-FAB, potentially aiding in standardizing post-treatment surveillance. PATIENT SUMMARY: Focal therapy has emerged as a promising approach for managing localized prostate cancer, but limitations in current imaging techniques present significant challenges for post-treatment surveillance. The Prostate Imaging after Focal Ablation (PI-FAB) scoring system showed high sensitivity for detecting in-field recurrence of clinically significant prostate cancer. However, its low specificity and positive predictive value necessitate further refinement. Larger, more comprehensive studies are needed to fully validate its clinical utility.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。