Development of a Highly Sensitive Humidity Sensor Based on a Piezoelectric Micromachined Ultrasonic Transducer Array Functionalized with Graphene Oxide Thin Film

基于压电微机械超声换能器阵列并功能化氧化石墨烯薄膜的高灵敏度湿度传感器的研制

阅读:1

Abstract

A novel relative humidity sensor that is based on a linear piezoelectric micromachined ultrasonic transducer (pMUT) array was proposed and microfabricated for high sensitivity, fast response, and good stability. The humidity-sensitive graphene oxide (GO) film was deposited on the pMUT array with a facile drop-casting method and characterized by scanning electron microscope (SEM), atomic force microscope (AFM), and Fourier transform infrared spectrum (FTIR). With the humidity level ranging from 10% to 90% RH, the sensor exhibited a high sensitivity of 719 Hz/% RH and an extremely high relative sensitivity of 271.1 ppm/% RH. The humidity-sensing results also showed good short-term repeatability and long-term stability, fast response and recovery, and low hysteresis. Moreover, the temperature coefficient of frequency (TCF) of the present humidity sensor was investigated and it could be easily compensated owing to the pMUT array structure design. This work confirmed that the GO functionalized pMUT is an excellent candidate in humidity detection and it may enable many potential applications, such as ultrasensitive mass detection and simultaneous detection of multiple parameters.