Study of saline optical coherence tomography-guided percutaneous coronary intervention (SOCT-PCI Study)

盐水光学相干断层扫描引导经皮冠状动脉介入治疗研究(SOCT-PCI 研究)

阅读:1

Abstract

AIM: The aim of this study was to evaluate the feasibility of heparinised saline as flushing media for frequency-domain optical coherence tomography (FD-OCT) image acquisition during percutaneous coronary intervention (PCI) optimisation. METHODS AND RESULTS: Twenty-seven patients undergoing FD-OCT-guided PCI were enrolled. Heparinised saline was injected into the coronary during FD-OCT image acquisition. A total of 118 runs were analysed for image quality and diagnostic value. FD-OCT runs were categorised as follows: good runs (GRs), clinically usable runs (CURs) and clinically not usable runs (NURs); GRs and CURs were combined as clinically effective runs (ERs). Saline FD-OCT enabled visualisation of all possible coronary lesions. Of the 118 runs analysed, 61%, 27.1%, 11.9% and 88.1% were GRs, CURs, NURs and ERs, respectively. Sixty-one percent of total runs were left coronary system (LCS) and 39% were right coronary system (RCS) runs. Among LCS runs, 55.6%, 30.6%, 13.8% and 86.2% were GRs, CURs, NURs and ERs, respectively. Among RCS runs, 69.6%, 21.7%, 8.7% and 91.3% were GRs, CURs, NURs and ERs, respectively. CONCLUSION: This is the first study to demonstrate the technical feasibility of isolated saline FD-OCT for PCI optimisation.