Validation of immunoassay for protein biomarkers: bioanalytical study plan implementation to support pre-clinical and clinical studies

蛋白质生物标志物的免疫测定验证:实施生物分析研究计划以支持临床前和临床研究

阅读:12
作者:Marie-Anne Valentin, Shenglin Ma, An Zhao, François Legay, Alexandre Avrameas

Abstract

Biomarkers have emerged as an important tool to optimize the benefit/risk ratio of therapeutics. The scientific impact of biomarker studies is directly related to the quality of the underlying data. It is therefore important that guidance be established for validation of assays used to support drug development. This paper specifically focuses on validation of immunoassay for protein biomarker to support pre-clinical and clinical studies. Therapeutics (small- and macro-molecules) and their respective target/ligand are out of scope. This paper describes the implementation of a bioanalytical study plan for the validation of immunoassays to support decision-making biomarkers and biomarker selection during preclinical and clinical studies. It establishes the complete operating procedure as well as the parameters and their respective acceptance criteria and defines milestones and decision points to be followed during the assay validation that should result in high quality bioanalytical data in a limited timeframe and with reduced costs. The bioanalytical study plan can be applied to the validation of a wild range of immunoassay technology such as monoplex ELISA, automated analyzer, multiplex assays or cutting edge technology. Before any validation, a feasibility study is performed to assess the performance of the immunoassay using biological samples which should mimic the clinical population. The feasibility study addresses the likelihood that an assay will be able to achieve its intended purpose with parallelism being the most critical element (milestone 1). At the end of the feasibility study, a decision is taken to either continue with the validation or change the assay (milestone 2). The milestone 3 consists of the establishment of the nominal value of quality control to be used during the validation. The quality controls used to validate an assay should preferentially be prepared using neat (non-spiked) biological matrix (ideally derived from the specific trial population). The last milestone (milestone 4), the formal validation, includes demonstration of the assay performance meeting accuracy and precision acceptance criteria within (intra-run) and between (inter-run) validation runs for each QC sample. Validation also includes the assessment of stability of the protein biomarker in the biological matrix. It is recognized that the extent of the validation should be correlated to the intended use of the data and the assay acceptance criteria should take into consideration the study objective(s), nature of the methodology and the biological variability of the biomarker.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。