Proteomics investigation of the changes in serum proteins after high- and low-flux hemodialysis

高通量和低通量血液透析后血清蛋白质变化的蛋白质组学研究

阅读:4
作者:Shuai Han, Kaiguang Yang, Hong Zhu, Jianhui Liu, Lihua Zhang, Jiuyang Zhao

Conclusions

Serum protein levels differentially changed after high- and low-flux HD. Long-term effects should be observed in future studies.

Methods

Before and after HD, serum samples were obtained from two selected patients who were treated with a Polyflux 140 H high-flux dialyzer and a Polyflux 14 L low-flux dialyzer during two continuous therapy sessions. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) was performed to identify the proteins.

Purpose

This study aimed to use proteomics

Results

A total of 212 and 203 serum proteins were identified after high-flux and low-flux HD, respectively. After high-flux HD, 21 proteins increased, and 132 proteins decreased. After low-flux HD, 87 proteins increased, and 45 proteins decreased. High-flux HD led to a significantly greater reduction in protein levels than low-flux HD (0.73 ± 0.13 vs. 0.84 ± 0.18, p = .00). Among the increased and decreased proteins, the isoelectric point (pI) values mainly ranged from 5 to 7, and the molecular weights (Mws) were mostly smaller than 30 kDa. The serum proteins showed no difference in pI or Mw for high- and low-flux HD. Gene ontology (GO) analysis showed that the detected proteins were related to immune system processes and complement activation. Conclusions: Serum protein levels differentially changed after high- and low-flux HD. Long-term effects should be observed in future studies.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。