Modeling lateral plume deflection in the wake of an elongated building

对细长建筑物尾流中的横向羽流偏转进行建模

阅读:2

Abstract

The plume dispersion model AERMOD provides an efficient method for modeling ground-level pollutant concentrations in wakes of buildings. In recent years, several studies have shown that the downwash algorithms within AERMOD often perform poorly in certain applications. Some studies have proposed modifications to the downwash algorithm in AERMOD to bring the model closer to representing the underlying physical processes associated with building downwash and closer to more accurately modeling observed pollutant concentrations. One such study by Monbureau et al. (2018) made changes to the model that significantly improved its ability to model ground level concentrations for a simple case of a single rectangular building with an elevated, effluent-emitting stack experiencing winds perpendicular to the upwind side of the building. The present study introduces a simple algorithm to enhance AERMOD's ability to appropriately match the dispersion pattern in the complex flow case of non-orthogonal winds. This algorithm, which is based on a rich set of Large-Eddy Simulations (LES), applies to a variety of building dimensions, stack locations, and stack heights. A sensitivity analysis demonstrates how additional modifications to the downwash algorithm may further improve AERMOD in modeling the spatial location of observed ground-level effluent.