STFM FOUNDATION GIVES GRANTS TO 3 STFM COLLABORATIVES

STFM基金会向3个STFM合作组织提供资助

阅读:1

Abstract

IMPORTANCE: Recommendations in the United States suggest limiting the number of patient records displayed in an electronic health record (EHR) to 1 at a time, although little evidence supports this recommendation. OBJECTIVE: To assess the risk of wrong-patient orders in an EHR configuration limiting clinicians to 1 record vs allowing up to 4 records opened concurrently. DESIGN, SETTING, AND PARTICIPANTS: This randomized clinical trial included 3356 clinicians at a large health system in New York and was conducted from October 2015 to April 2017 in emergency department, inpatient, and outpatient settings. INTERVENTIONS: Clinicians were randomly assigned in a 1:1 ratio to an EHR configuration limiting to 1 patient record open at a time (restricted; n = 1669) or allowing up to 4 records open concurrently (unrestricted; n = 1687). MAIN OUTCOMES AND MEASURES: The unit of analysis was the order session, a series of orders placed by a clinician for a single patient. The primary outcome was order sessions that included 1 or more wrong-patient orders identified by the Wrong-Patient Retract-and-Reorder measure (an electronic query that identifies orders placed for a patient, retracted, and then reordered shortly thereafter by the same clinician for a different patient). RESULTS: Among the 3356 clinicians who were randomized (mean [SD] age, 43.1 [12.5] years; mean [SD] experience at study site, 6.5 [6.0] years; 1894 females [56.4%]), all provided order data and were included in the analysis. The study included 12 140 298 orders, in 4 486 631 order sessions, placed for 543 490 patients. There was no significant difference in wrong-patient order sessions per 100 000 in the restricted vs unrestricted group, respectively, overall (90.7 vs 88.0; odds ratio [OR], 1.03 [95% CI, 0.90-1.20]; P = .60) or in any setting (ED: 157.8 vs 161.3, OR, 1.00 [95% CI, 0.83-1.20], P = .96; inpatient: 185.6 vs 185.1, OR, 0.99 [95% CI, 0.89-1.11]; P = .86; or outpatient: 7.9 vs 8.2, OR, 0.94 [95% CI, 0.70-1.28], P = .71). The effect did not differ among settings (P for interaction = .99). In the unrestricted group overall, 66.2% of the order sessions were completed with 1 record open, including 34.5% of ED, 53.7% of inpatient, and 83.4% of outpatient order sessions. CONCLUSIONS AND RELEVANCE: A strategy that limited clinicians to 1 EHR patient record open compared with a strategy that allowed up to 4 records open concurrently did not reduce the proportion of wrong-patient order errors. However, clinicians in the unrestricted group placed most orders with a single record open, limiting the power of the study to determine whether reducing the number of records open when placing orders reduces the risk of wrong-patient order errors. TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT02876588.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。