Reducing the Impacts of Biofouling in RO Membrane Systems through In Situ Low Fluence Irradiation Employing UVC-LEDs

通过使用 UVC-LED 进行原位低通量照射来减少 RO 膜系统中生物污染的影响

阅读:8
作者:Philipp Sperle, Christian Wurzbacher, Jörg E Drewes, Bertram Skibinski

Abstract

Biofouling is a major concern for numerous reverse osmosis membrane systems. UV pretreatment of the feed stream showed promising results but is still not an established technology as it does not maintain a residual effect. By conducting accelerated biofouling experiments in this study, it was investigated whether low fluence UV in situ treatment of the feed using UVC light-emitting diodes (UVC-LEDs) has a lasting effect on the biofilm. The application of UVC-LEDs for biofouling control is a novel hybrid technology that has not been investigated, yet. It could be shown that a low fluence of 2 mJ∙cm-2 delays biofilm formation by more than 15% in lab-scale experiments. In addition, biofilms at the same feed channel pressure drop exhibited a more than 40% reduced hydraulic resistance. The delay is probably linked to the inactivation of cells in the feed stream, modified adsorption properties or an induced cell cycle arrest. The altered hydraulic resistance might be caused by a change in the microbial community, as well as reduced adenosine triphosphate levels per cells, possibly impacting quorum sensing and extracellular polymeric substances production. Due to the observed biofilm attributes, low fluence UV-LED in situ treatment of the feed stream seems to be a promising technology for biofouling control.